Injection rate (ppm)
Origin CP PP 500 1000 1500 2500
oC oC Pour point values (oC)
Mexico + 8 + 3 -12 -18
Asia – 9 – 9 -27 -30 -36
North Sea +10 + 6 -12 -24 -27
North Africa + 5 + 0 -21 -27 -33
North Sea +15 +15 – 6 -12
Injection rate (ppm)
Origin CP CFPP 250 500 1500 2500
oC oC CFPP values (oC)
North Sea – 8 -11 -15 -17 -18 -20
North Sea -15 -18 -23 -28 -30 -32
North Africa – 1 – 2 – 3 – 5 – 9 -14
North Africa – 7 – 9 -13 -17 -24 -28
USSR – 4 – 5 – 7 -10 -18 -25
(CFPP : Cloud filter plugging point)
(CP : Cloud point)
(PP : Pour point)
The exact reduction of pour point and cloud filter plugging point and injection rate depends on the type and the quality of the fuel and could be performed by trials.
In a proportion of 1 liter in 2.500 liters diesel:
Decreases the pour point from: -9 oC to – 27 oC approximately.
Decreases the cloud filter plugging point from: – 5 C to – 10 oC approximately.
In a proportion of 1 liter in 1000 liters diesel:
Decreases the pour point from: -9 oC to – 30 oC approximately.
Decreases the cloud filter plugging point from: – 5 C to – 14 oC approximately.
In a proportion of 2 liters in 1000 liters diesel:
Decreases the pour point from: -9 oC to – 34 oC approximately.
Decreases the cloud filter plugging point from: – 5 oC to – 22 oC approximately
By increasing the dosage, the pour point and the filter plugging point are decreased.